BMC1-63
The 16A-63A single-pole contactor is an AC contactor with a width of only 18mm. The product uses M5 wiring screws, and the maximum wiring capacity is 25mm².The product adopts a
hidden coil terminal design, which has a larger and safer electrical gap.
BWF-T01
BWF series WIFI smart switch controller, the outer shell is made of Pc flame retardant material, which is safer to use; the maximum load of 230V/2A can be extended to 125A through the
contactor, using standard WIFI: 2.4GHzb/g/n.
DIN Rail Meter
The BV series rail-type voltmeter can be used for voltage indication in various electrical situations. The products are divided into single-phase indication and three-phase indication. The voltmeter adopts a rail-type modular design and can be installed in conjunction with other rail-type modular products. The rail-type voltmeter complies with the standards GB/T 140848.4, IEC60947-4-1
BIR-32 Impulse Relay
BIR series pulse relay coils are triggered by pulses and their contacts close. The product has two stable mechanical positions and the contacts will open when the next pulse comes.
Each received pulse will invert the position of the contacts, controllable by an unlimited number of push buttons. And it has the characteristics of zero power consumption.
Pulse relays can be used to control lighting circuits through buttons. The circuit consists of incandescent lamps, halogen lamps, etc. (resistive load), fluorescent lamps, discharge lamps, etc.(inductive load).
Comply with standards: GB/T 21711.1, IEC60669-2-1
BMC7-16-32 1P
BMC7 miniature automatic AC contactor (also known as modular contactor, construction contactor) is mainly suitable for power systems with AC 50Hz/60Hz, rated
operating voltage up to 400V, and rated operating current up to 63A, in AC-1 , AC-7a (non-inductive or low-inductive loads, resistance furnaces, household
appliances and low-inductive loads for similar purposes) use category, used for remote switches and control circuits, and can also be used to control household
motor loads. Household contactors are not used to break short-circuit current, so appropriate short-circuit protection appliances (such as small circuit breakers)
should be selected when used. Comply with standards IEC61095, GB17885. IEC60947-4-1,GB/T 14048.4.
BCH8-100 4P AC contactor
BCH8 miniature automatic AC contactor (also known as modular contactor, construction contactor) is mainly suitable for power systems with AC 50Hz/60Hz, rated operating voltage up to 400V, and rated operating current up to
125A, in AC-1 (non-inductive or low-inductive loads, resistance furnaces, household appliances and similar low-inductive loads) use category, used for remote switches and control circuits, and can also be used to control
household motor loads. Household contactors are not used to break short-circuit current, so appropriate short-circuit protection appliances (such as small circuit breakers) should be selected when using them. Comply with
standards IEC61095, GB17885.IEC60947-4-1,GB/T 14048.4.
BCH8-100 2P AC contact...
BCH8 miniature automatic AC contactor (also known as modular contactor, construction contactor) is mainly suitable for power systems with AC 50Hz/60Hz, rated operating voltage up to 400V, and rated operating current up to
125A, in AC-1 (non-inductive or low-inductive loads, resistance furnaces, household appliances and similar low-inductive loads) use category, used for remote switches and control circuits, and can also be used to control
household motor loads. Household contactors are not used to break short-circuit current, so appropriate short-circuit protection appliances (such as small circuit breakers) should be selected when using them. Comply with
standards IEC61095, GB17885.IEC60947-4-1,GB/T 14048.4.
BCH8-63M 4P manual con...
BCH8 miniature automatic AC contactor (also known as modular contactor, construction contactor) is mainly suitable for power systems with AC 50Hz/60Hz, rated operating voltage up to 400V, and rated operating current up to
125A, in AC-1 (non-inductive or low-inductive loads, resistance furnaces, household appliances and similar low-inductive loads) use category, used for remote switches and control circuits, and can also be used to control
household motor loads. Household contactors are not used to break short-circuit current, so appropriate short-circuit protection appliances (such as small circuit breakers) should be selected when using them. Comply with
standards IEC61095, GB17885.IEC60947-4-1,GB/T 14048.4.
BCH8-63 4P AC contactor
BCH8 miniature automatic AC contactor (also known as modular contactor, construction contactor) is mainly suitable for power systems with AC 50Hz/60Hz, rated operating voltage up to 400V, and rated operating current up to
125A, in AC-1 (non-inductive or low-inductive loads, resistance furnaces, household appliances and similar low-inductive loads) use category, used for remote switches and control circuits, and can also be used to control
household motor loads. Household contactors are not used to break short-circuit current, so appropriate short-circuit protection appliances (such as small circuit breakers) should be selected when using them. Comply with
standards IEC61095, GB17885.IEC60947-4-1,GB/T 14048.4.
BCH8-63M 2P manual con...
BCH8 miniature automatic AC contactor (also known as modular contactor, construction contactor) is mainly suitable for power systems with AC 50Hz/60Hz, rated operating voltage up to 400V, and rated operating current up to
125A, in AC-1 (non-inductive or low-inductive loads, resistance furnaces, household appliances and similar low-inductive loads) use category, used for remote switches and control circuits, and can also be used to control
household motor loads. Household contactors are not used to break short-circuit current, so appropriate short-circuit protection appliances (such as small circuit breakers) should be selected when using them. Comply with
standards IEC61095, GB17885.IEC60947-4-1,GB/T 14048.4.
BCH8-63 2P AC contactor
BCH8 miniature automatic AC contactor (also known as modular contactor, construction contactor) is mainly suitable for power systems with AC 50Hz/60Hz, rated operating voltage up to 400V, and rated operating current up to
125A, in AC-1 (non-inductive or low-inductive loads, resistance furnaces, household appliances and similar low-inductive loads) use category, used for remote switches and control circuits, and can also be used to control
household motor loads. Household contactors are not used to break short-circuit current, so appropriate short-circuit protection appliances (such as small circuit breakers) should be selected when using them. Comply with
standards IEC61095, GB17885.IEC60947-4-1,GB/T 14048.4.